Basic Info.
Application
Electrical Device/Domestic Appliance, etc
Range of Application
Electrical Device/Domestic Appliance, etc
Color
Black, Red, Yellow, Blue, White
Transport Package
Roll in
Product Description
450/750V Copper Core PVC Insulated Electric Wire
Application
A. It can be applied to be installation and connection for electrical device, equipment power device, domestic appliance, instrument,lighting circuit, and automation device.
B. The feature of flame retardant cable is not easy to be fired and can control the flame into certain restriction and slow the fire speed after fire. So it can be applied to the occasion with high request of flame retardant.
C. Flame cable can be divided into 4 grade: A,B,C,D and the Grade A is the best flame retardant grade.
D. Beside the cable can transfer power at the normal condition, it can also keep a period of safe operation under fire. It can be applied for the occasion with request of fire resistance.
Pruduct Structure
Reference Data of the Product Structure: IEC 60227
1. 01(BV)Cable
Nominal Section of the conductor (mm2) | Conductor Types | Cable Reference Diameter (mm) | Cable Average Diameter (mm) | Cable Reference Weight (kg/km) | Maximum Resistance of the conductor at 20ºC (/km) | Minumum Insulation Resistance at 70ºC (M·km) | Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
BV | Minimum | Maximum | BV |
1.5 | 1 | 2.82 | 2.6 | 3.2 | 19.70 | 12.1 | 0.011 | 18 |
1.5 | 2 | 3.00 | 2.7 | 3.3 | 20.31 | 12.1 | 0.010 | 18 |
2.5 | 1 | 3.43 | 3.2 | 3.9 | 31.20 | 7.41 | 0.010 | 25 |
2.5 | 2 | 3.69 | 3.3 | 4.0 | 32.82 | 7.41 | 0.009 | 25 |
4 | 1 | 3.90 | 3.6 | 4.4 | 46.08 | 4.61 | 0.0085 | 33 |
4 | 2 | 4.20 | 3.8 | 4.6 | 47.45 | 4.61 | 0.0077 | 33 |
6 | 1 | 4.41 | 4.1 | 5.0 | 65.71 | 3.08 | 0.0070 | 42 |
6 | 2 | 4.77 | 4.3 | 5.2 | 67.19 | 3.08 | 0.0065 | 42 |
10 | 1 | 5.65 | 5.3 | 6.4 | 109.09 | 1.83 | 0.0070 | 58 |
10 | 2 | 6.13 | 5.6 | 6.7 | 113.07 | 1.83 | 0.0065 | 58 |
16 | 2 | 7.18 | 6.4 | 7.8 | 170.90 | 1.15 | 0.0050 | 78 |
25 | 2 | 8.92 | 8.1 | 9.7 | 268.52 | 0.727 | 0.0050 | 105 |
35 | 2 | 10.06 | 9.0 | 10.9 | 362.82 | 0.524 | 0.0043 | 130 |
50 | 2 | 11.81 | 10.6 | 12.8 | 492.15 | 0.387 | 0.0043 | 155 |
70 | 2 | 13.61 | 12.1 | 14.6 | 694.19 | 0.268 | 0.0035 | 200 |
95 | 2 | 15.93 | 14.1 | 17.1 | 959.23 | 0.193 | 0.0035 | 250 |
120 | 2 | 17.54 | 15.6 | 18.8 | 1197.15 | 0.153 | 0.0032 | 290 |
150 | 2 | 19.49 | 17.3 | 20.9 | 1472.95 | 0.124 | 0.0032 | 335 |
185 | 2 | 21.80 | 19.3 | 23.3 | 1846.14 | 0.0991 | 0.0032 | 390 |
240 | 2 | 24.83 | 22.0 | 26.6 | 2416.54 | 0.0754 | 0.0032 | 470 |
300 | 2 | 27.67 | 24.5 | 29.6 | 3023.55 | 0.0601 | 0.0030 | 540 |
400 | 2 | 31.06 | 27.5 | 33.2 | 3851.72 | 0.0470 | 0.0028 | 635 |
2.02(RV)Cable
Nominal Section of the conductor (mm2) | Conductor Types | Cable Reference Diameter (mm) | Cable Average Diameter (mm) | Cable Reference Weight (kg/km) | Maximum Resistance of the conductor at 20ºC (Ω/km) | Minumum Insulation Resistance at 70ºC (MΩ·km) | Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
RV | Minimum | Maximum | RV |
1.5 | 5 | 3.00 | 2.8 | 3.4 | 20.30 | 13.3 | 0.010 | 18 |
2.5 | 5 | 3.64 | 3.4 | 4.1 | 31.59 | 7.98 | 0.009 | 25 |
4 | 5 | 4.21 | 3.9 | 4.8 | 47.54 | 4.95 | 0.0070 | 33 |
6 | 5 | 4.81 | 4.4 | 5.3 | 67.42 | 3.3 | 0.0060 | 42 |
10 | 5 | 6.28 | 5.7 | 6.8 | 118.00 | 1.81 | 0.0056 | 58 |
16 | 5 | 7.20 | 6.7 | 8.1 | 169.44 | 1.21 | 0.0046 | 78 |
25 | 5 | 10.10 | 8.4 | 10.2 | 269.71 | 0.78 | 0.0044 | 105 |
35 | 5 | 11.23 | 9.7 | 11.7 | 364.35 | 0.554 | 0.0038 | 130 |
50 | 5 | 13.75 | 11.5 | 13.9 | 522.86 | 0.386 | 0.0037 | 155 |
70 | 5 | 15.40 | 13.2 | 16.0 | 720.89 | 0.272 | 0.0032 | 200 |
95 | 5 | 18.15 | 15.1 | 18.2 | 953.89 | 0.206 | 0.0032 | 250 |
120 | 5 | 19.70 | 16.7 | 20.2 | 1199.28 | 0.161 | 0.0029 | 290 |
150 | 5 | 21.10 | 18.6 | 22.5 | 1485.62 | 0.129 | 0.0029 | 335 |
185 | 5 | 24.03 | 20.6 | 24.9 | 1824.52 | 0.106 | 0.0029 | 390 |
240 | 5 | 26.70 | 23.5 | 28.4 | 2389.69 | 0.0801 | 0.0028 | 470 |
3.05(BV)Cable
Nominal Section of the conductor (mm2) | Conductor Types | Cable Reference Diameter (mm) | Cable Average Diameter (mm) | Cable Reference Weight (kg/km) | Maximum Resistance of the conductor at 20ºC (Ω/km) | Minumum Insulation Resistance at 70ºC (MΩ·km) | Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
BV | Minimum | Maximum | BV |
0.5 | 1 | 2.04 | 1.9 | 2.3 | 8.16 | 36.0 | 0.015 | 9 |
0.75 | 1 | 2.21 | 2.1 | 2.5 | 10.71 | 24.5 | 0.012 | 12 |
1 | 1 | 2.37 | 2.2 | 2.7 | 13.48 | 18.1 | 0.011 | 14 |
4.06(RV)Cable
Nominal Section of the conductor (mm2) | Conductor Types | Cable Reference Diameter (mm) | Cable Average Diameter (mm) | Cable Reference Weight (kg/km) | Maximum Resistance of the conductor at 20ºC (Ω/km) | Minumum Insulation Resistance at 70ºC (MΩ·km) | Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
RV | Minimum | Maximum | RV |
0.5 | 5 | 2.18 | 2.1 | 2.5 | 8.58 | 39.0 | 0.013 | 9 |
0.75 | 5 | 2.43 | 2.2 | 2.7 | 11.50 | 26.0 | 0.011 | 12 |
1 | 5 | 2.52 | 2.4 | 2.8 | 14.00 | 19.5 | 0.010 | 14 |
5.10(BVV)Cable
Core No.×Nominal Section of the conductor (mm2) | Conductor Types | Cable Reference Diameter (mm) | Cable Average Diameter (mm) | Cable Reference Weight (kg/km) | Maximum Resistance of the conductor at 20ºC (Ω/km) | Minumum Insulation Resistance at 70ºC (MΩ·km) | Reference Current (Ambient temperature is 40ºC,highest temperature is 70ºC) (A) |
BVV | Minimum | Maximum | BVV |
2×1.5 | 1 | 9.36 | 7.6 | 10.0 | 98.94 | 12.1 | 0.011 | 18 |
2×1.5 | 2 | 9.72 | 7.8 | 10.5 | 103.09 | 12.1 | 0.010 | 18 |
2×2.5 | 1 | 10.56 | 8.6 | 11.5 | 130.99 | 7.41 | 0.010 | 25 |
2×2.5 | 2 | 11.08 | 9.0 | 12.0 | 138.55 | 7.41 | 0.009 | 25 |
2×4 | 1 | 11.50 | 9.6 | 12.5 | 171.31 | 4.61 | 0.0085 | 33 |
2×4 | 2 | 12.10 | 10.0 | 13.0 | 179.24 | 4.61 | 0.0077 | 33 |
2×6 | 1 | 12.52 | 10.5 | 13.5 | 218.41 | 3.08 | 0.0070 | 42 |
2×6 | 2 | 13.24 | 11.0 | 14.0 | 227.77 | 3.08 | 0.0065 | 42 |
2×10 | 1 | 15.64 | 13.0 | 16.5 | 361.55 | 1.83 | 0.0070 | 65 |
2×10 | 2 | 16.70 | 13.5 | 17.5 | 384.71 | 1.83 | 0.0065 | 65 |
2×16 | 2 | 18.80 | 15.5 | 20.0 | 532.01 | 1.15 | 0.0052 | 87 |
2×25 | 2 | 22.64 | 18.5 | 24.0 | 798.61 | 0.727 | 0.0050 | 110 |
2×35 | 2 | 25.72 | 21.0 | 27.5 | 1055.97 | 0.524 | 0.0044 | 140 |
3×1.5 | 1 | 9.8 | 8.0 | 10.5 | 124.61 | 12.1 | 0.011 | 15 |
3×1.5 | 2 | 10.19 | 8.2 | 11.0 | 129.71 | 12.1 | 0.010 | 15 |
3×2.5 | 1 | 11.10 | 9.2 | 12.0 | 168.94 | 7.41 | 0.010 | 21 |
3×2.5 | 2 | 11.66 | 9.4 | 12.5 | 178.67 | 7.41 | 0.009 | 21 |
3×4 | 1 | 12.12 | 10.0 | 13.0 | 228.20 | 4.61 | 0.0085 | 28 |
3×4 | 2 | 12.76 | 10.5 | 13.5 | 238.21 | 4.61 | 0.0077 | 28 |
3×6 | 1 | 13.62 | 11.5 | 14.5 | 307.47 | 3.08 | 0.0070 | 36 |
3×6 | 2 | 14.40 | 12.0 | 15.5 | 319.96 | 3.08 | 0.0065 | 36 |
3×10 | 1 | 16.52 | 14.0 | 17.5 | 476.74 | 1.83 | 0.0070 | 56 |
3×10 | 2 | 17.67 | 14.5 | 19.0 | 507.40 | 1.83 | 0.0065 | 56 |
3×16 | 2 | 20.34 | 16.5 | 21.5 | 726.41 | 1.15 | 0.0052 | 74 |
3×25 | 2 | 24.05 | 20.5 | 26.0 | 1074.22 | 0.727 | 0.0050 | 98 |
3×35 | 2 | 27.31 | 22.0 | 29.0 | 1431.17 | 0.524 | 0.0044 | 120 |
4×1.5 | 1 | 10.51 | 8.6 | 11.5 | 159.43 | 12.1 | 0.011 | 15 |
4×1.5 | 2 | 10.95 | 9.0 | 12.0 | 165.62 | 12.1 | 0.010 | 15 |
4×2.5 | 1 | 11.96 | 10.0 | 13.0 | 216.48 | 7.41 | 0.010 | 21 |
4×2.5 | 2 | 12.59 | 10.0 | 13.5 | 228.55 | 7.41 | 0.009 | 21 |
4×4 | 1 | 13.49 | 11.5 | 14.4 | 296.50 | 4.61 | 0.0085 | 28 |
4×4 | 2 | 14.22 | 12.0 | 15.0 | 309.46 | 4.61 | 0.0077 | 28 |
4×6 | 1 | 15.13 | 12.5 | 16.0 | 398.92 | 3.08 | 0.0070 | 36 |
4×6 | 2 | 15.99 | 13.0 | 17.0 | 414.94 | 3.08 | 0.0065 | 36 |
4×10 | 1 | 17.93 | 15.5 | 19.0 | 594.97 | 1.83 | 0.0070 | 56 |
4×10 | 2 | 19.20 | 16.0 | 20.5 | 633.59 | 1.83 | 0.0065 | 56 |
4×16 | 2 | 22.14 | 18.0 | 35.5 | 916.62 | 1.15 | 0.0052 | 74 |
4×25 | 2 | 27.09 | 22.5 | 28.5 | 1414.08 | 0.727 | 0.0050 | 98 |
4×35 | 2 | 28.84 | 24.5 | 32.0 | 1826.39 | 0.524 | 0.0044 | 120 |
5×1.5 | 1 | 11.31 | 9.4 | 12.0 | 191.08 | 12.1 | 0.011 | 15 |
5×1.5 | 2 | 11.79 | 9.8 | 12.5 | 198.39 | 12.1 | 0.010 | 15 |
5×2.5 | 1 | 12.93 | 11.0 | 14.0 | 260.97 | 7.41 | 0.010 | 21 |
5×2.5 | 2 | 13.63 | 11.0 | 14.5 | 275.46 | 7.41 | 0.009 | 21 |
5×4 | 1 | 15.00 | 12.5 | 16.0 | 370.96 | 4.61 | 0.0085 | 28 |
5×4 | 2 | 15.81 | 13.0 | 17.0 | 387.08 | 4.61 | 0.0077 | 28 |
5×6 | 1 | 16.37 | 13.5 | 17.5 | 482.44 | 3.08 | 0.0070 | 36 |
5×6 | 2 | 17.34 | 14.5 | 18.5 | 501.42 | 3.08 | 0.0065 | 36 |
5×10 | 1 | 19.50 | 17.0 | 21.0 | 725.11 | 1.83 | 0.0070 | 56 |
5×10 | 2 | 20.94 | 17.5 | 22.0 | 771.84 | 1.83 | 0.0065 | 56 |
5×16 | 2 | 24.57 | 20.5 | 26.0 | 1142.09 | 1.15 | 0.0052 | 74 |
5×25 | 2 | 29.61 | 24.5 | 31,5 | 1732.02 | 0.727 | 0.0050 | 98 |
5×35 | 2 | 33.09 | 27.0 | 35.0 | 2272.06 | 0.524 | 0.0044 | 120 |
Notes: Conductor Types--1st type is solid conductor;2nd type is stranded conductor;5th type is stranded soft conductor;
which are suitable for different applications.
Address:
T1-1601, Capitamall Westgate, Gutian 2nd Road, Wuhan ,P.R.China, 430035
Business Type:
Manufacturer/Factory, Trading Company, Group Corporation
Business Range:
Electrical & Electronics
Management System Certification:
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001
Company Introduction:
Aerospace Electric Group Co., Ltd (AEG for short), formerly known as Wuhan Cable Group Co., Ltd., is an state-owned enterprise subsidiary to the 9th Research Institute of China Aerospace Science and Technology Corporation (CASC). Specialized in manufacturing and R&D of excellent quality electric wires & cables with over 60 years′ professional experience, AEG now integrates Conductor Business Division, Power Cable Business Division, International trade Division, Aerospace Rich Special Cable Co., Ltd, Hubei Aerospace Cable Co., Ltd and Hubei Longsky Communication Technology Co., Ltd. Now AEG has 2080 employees, including 300 senior professionals. The total asset of the group has reached 3.85billion RMB.
AEG imports a series of advanced production and testing equipment from Germany, the United States, Britain, Italy, etc., which helps to achieve the production capability of 30, 000 tons of aluminum alloy conductors, 80, 000 tons of aluminum conductor steel-reinforced(ACSR), 24, 000 tons of aluminum-clad steel wires, 30, 000 km. Of LV and MV cables and 50, 000 km. Of special cables and wires. The overall production scale reaches 5 billion RMB.
Products of AEG are applicable to power production, power supply, construction and installation etc., We supplied for Daya Bay Nuclear Power Plant, Three Gorges Hydroelectric Power Station, Datang Power Plant, Wuhan Tianhe International Airport, Guangzhou---Wuhan Express Railway, Daqing Oil Field, Tiananmen Square reconstruction, Wuhan Metro, etc. The military-related products are used by Xichang Satellite Base, Chengdu Airport, the 2ND Artillery Corps, Dongfeng Motor, Naval Base and other large scale nationally focused engineering construction. They are also exported to more than 20 countries and regions including USA, Germany, Greece and Pakistan. Many products are granted with national, ministerial, provincial and municipal Excellent New Product Award and Prize for Progress in Science and Technology while others obtain national utility model patents.
We′re pleased to get your Inquiry and we will come back to as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective.